| Control Functions |
type |
256 |
260 |
261 |
262 |
264 |
268 |
265 |
269 |
| Boiler Operation |
|
|
|
|
|
|
|
|
|
Number of Stages |
1 |
1 |
2 |
2 |
4 |
9 |
3 |
1 |
|
Boiler Differential |
A/M |
A/M |
A/M |
A/M |
A/M |
A/M |
A/M |
|
|
Boiler Minimum Supply |
|
M |
M |
M |
M |
M |
M |
M |
|
Boiler Outdoor Reset |
|
|
|
|
|
|
|
|
|
Boiler Post Purge |
|
F |
F |
M |
A/M |
A/M |
A/M |
|
|
Characterized Heating Curve |
|
|
|
|
|
|
|
|
|
Equal Run Time Rotation |
|
|
|
|
|
|
|||
Fire Delay |
|
F |
M |
M |
M |
M |
M |
F |
|
Fixed Last |
|
|
|
|
|||||
Fixed Lead |
|
|
|
||||||
Heating Curve |
|
|
|
||||||
Heating Curve Shift |
|
M |
A/M |
M |
A/M |
M |
M |
M |
A/M |
Indoor Temperature Feedback |
|
|
|
|
|||||
Interstage Delay |
|
A |
A |
A |
A |
A |
A |
||
Lo / Hi Fire Boiler Rotation |
|
|
|
||||||
Lockout Differential |
|
|
|||||||
Minimum On Time |
|
|
|||||||
PID Staging |
|
|
|
|
|
|
|||
Reset Ratio |
|
|
|||||||
Soft Start |
|
|
|||||||
Starting Water Temperature |
|
|
|||||||
Steam Established |
|
|
|||||||
Warm Weather Shut Down (WWSD) |
|
|
|
|
|
|
|
|
|
Water Temperature Boost |
|
A |
|
A/M |
M |
M |
M |
|
|
| Modulation Operation |
|
|
|
|
|
|
|
|
|
0 - 20 mA or 4 - 20 mA Outputs |
|
|
|||||||
Minimum and Maximum Modulation Settings |
|
|
|||||||
Parallel or Sequential Modulation |
|
|
|||||||
| Domestic Hot Water (DHW) Operation |
|
|
|
|
|
|
|
|
|
DHW Boiler Reset Override |
|
|
|
|
|
|
|||
DHW Condensing Boiler |
|
|
|
|
|
|
|||
DHW External Demand |
|
|
|
|
|
|
|||
DHW Internal Demand (Sensor) |
|
|
|||||||
DHW Post Purge |
|
|
|
|
|
|
|||
DHW Priority |
|
|
|
|
|
|
|||
DHW Setback |
|
|
|
|
|
|
|||
| Setpoint Operation |
|
|
|
|
|
|
|
|
|
Setpoint Boiler Reset Override |
|
|
|
|
|
|
|
|
|
Setpoint Priority |
|
|
|
|
|
|
|
|
|
| Protection |
|
|
|
|
|
|
|
|
|
Pump Exercising |
|
|
|
|
|
|
|
|
|
| Setback |
|
|
|
|
|
|
|
|
|
Timer, 7 Day |
|
||||||||
Water Temperature Boost (Indoor Feedback) |
|
|
|
||||||
Water Temperature Setback |
|
|
|
|
|
|
|
|
|
Zone Temperature Setback |
|
|
|
||||||
| Display |
|
|
|
|
|
|
|
|
|
Temperature Display |
|
|
|
|
|
|
|
|
|
Usage Display |
|
|
|
|
|
||||
| Other |
|
|
|
|
|
|
|
|
|
120 or 240 V (ac) Rated Relay Outputs |
|
|
|
|
|
|
|
|
|
Auto Test |
|
|
|
|
|
|
|
|
|
CSA C US Approved |
|
|
|
|
|
|
|
|
|
Error Messages |
|
|
|
|
|
|
|
|
|
Function Indicators |
|
|
|
|
|
|
|
|
|
Locking Cover Option |
|
|
|
|
|
|
|
|
|
Plug In System |
|
|
|
|
|
|
|
|
|
|
A = Automatic Adjustment, F = Fixed, M = Manual |
|||||||||