Search tekmarcontrols.com

arrow Zone Expansion Module 326 - Three Zone Pumps

Zone Expansion Module 326

Control Description The Zone Expansion Manager 326 is designed to simplify the wiring between tN4 thermostats and zone pumps. The 326 supplies power to the tekmarNet®4 (tN4) thermostats and connected zone pumps.

 

Control

Microprocessor PID control; This is not a safety (limit) control

Packaged Weight

1.15 lb. (522 g)

Dimensions

3-5/8" H x 5-3/8" W x 9/16" D (92 x 137 x 14 mm)

Approvals

CSA C US, CSA/UL 61010-1, meets Class B: ICES and FCC Part 15

Ambient Conditions

Indoor use only, 32 to 122°F (0 to 50°C).

RH equal to or less than 80% to 88°F (31°C), down to 50% from 104 to 122°F (40 to 50°C)

Altitude <2000 m, Installation Category II, Pollution Category 2

Power Supply

Provided by interconnected Zone Manager

Zone Pump C1 Relay

115 V (ac) 5 A 1/4 hp, pilot duty 240 VA

Zone Pump C2 Relay

115 V (ac) 5 A 1/4 hp, pilot duty 240 VA

Zone Pump C3 Relay

115 V (ac) 5 A 1/4 hp, pilot duty 240 VA

Zone Group Pump C Relay

115 V (ac) 5 A 1/4 hp, pilot duty 240 VA

Combined Relay Load

10 A Maximum

 

 


Quick
links:

002 003 004 005 007 011 024 031 032 033 039 040 060 062 070 071 072 073 076 077 078 079 080 081 082 083 084 090 092 132 150 152 153 155 156 157 161 162 256 257 260 261 262 263 264 265 268 269 270 275 279 325 326 335 336 337 345 346 356 360 361 362 363 364 365 369 374 420 421 422 423 440 441 444 479 480 481 483 507 508 509 510 511 512 537 538 540 541 542 543 544 545 546 650 664 665 667 704 710 720 741