Control Description The Mixing Station 704 represents a breakthrough in the design, control and installation of radiant systems. The patent pending design combines a variable speed injection mixing control (RMC), injection circulator, system circulator, and air elimination into a single unit. Extremely versatile, the Mixing Station 704 can be set up to operate as an outdoor reset control, a setpoint control or a delta T limiting control.
Control |
|
Microprocessor PID control: This is not a safety (limit) control |
Ambient conditions |
|
Indoor use only, 32 to 185°F (0 to 85°C), <90% RH non-condensing |
Power Supply |
|
120 V (ac) +/- 10% 50/60 Hz 720 VA |
Var. Pump |
|
120 V (ac) 1 A 1/12 hp, fuse T1 A 250 V |
Sys / Pmp Relay |
|
120 V (ac) 5 A 1/4 hp, pilot duty 240 VA |
Boiler Relay |
|
120 V (ac) 5 A 1/4 hp, pilot duty 240 VA |
Demand |
|
24 V (ac) 0.1 VA or Dry contact |
Sensors |
|
NTC thermistor, 10 kΩ @ 77°F (25°C ±0.2°C) ß=3892 |
Included |
|
Outdoor Sensor 070, Universal Sensors 071 and 082 |
|
Quick 002 003 004 005 007 011 024 031 032 033 039 040 060 062 070 071 072 073 076 077 078 079 080 081 082 083 084 090 092 132 150 152 153 155 156 157 161 162 256 257 260 261 262 263 264 265 268 269 270 275 279 325 326 335 336 337 345 346 356 360 361 362 363 364 365 369 374 420 421 422 423 440 441 444 479 480 481 483 507 508 509 510 511 512 537 538 540 541 542 543 544 545 546 650 664 665 667 704 710 720 741 |