The tekmarNet®2 House Control 406 is designed to operate the equipment in a 2-pipe, single tank, hydronic heating and cooling system. It operates two heat pump stages (water-to-water or air-to-water) with a backup heat source (boiler or electric resistance). The heat pump provides either hot or chilled water to a storage tank loop and optional mixed temperature loop. For radiant heating, the water temperature is calculated using Outdoor Temperature Reset. For radiant cooling, the chilled water temperature is maintained at an adjustable setpoint, or is adjusted using dew-point reset with a humidity sensor. A backup boiler can provide an Outdoor Temperature Reset water temperature as well as domestic hot water and setpoint water temperatures. The 406 operates 4 on-board heating and cooling zones and is expandable up to 52 zones on the boiler, tank, and mix water temperatures.
Automatic differential for heat pump and boiler
Controls 2-stage heat pump
Controls on/off or modulating boiler
DHW Post Purge
DHW control with priority
Electric resistance backup (optional)
Exercising
Expandable up to 52 zones
Floor cooling capable
Four 24 V (ac) powered zone valve outputs
Indoor Temperature Feedback
Intelligent heat/cool switchover
One touch overrides (with optional User Switch)
Outdoor Temperature Reset
Setpoint operation
System setback (with optional timer)
Variable speed mixing control
Warm Weather Shut Down
Zone Synchronization
| Control | Microprocessor control. This is not a safety (limit) control |
| Packaged weight | 1.4 lb. (640 g) |
| Dimensions | 5.5" H x 5.5" W x 2.25" D (140 x 140 x 57 mm) |
| Enclosure | NEMA 1 rated, blue PC+ABS plastic |
| Approvals | CSA C US, meets class B: ICES & FCC Part 15 |
| Ambient conditions | Indoor use only, 32 to 104°F (0 to 40°C), RH 90% Noncondensing |
| Power supply | 24 V (ac) ±10% 60 Hz, 100 VA max, Class 2 |
| Control Load | 2 VA |
| Zone, Y1 and O/B Relays | 24 V (ac) 3.7 A combined |
| Y2, Backup Relays | 24 V (ac) 5 A |
| Pump Power | 115 V (ac) 12 A |
| Pump Relays | 115 V (ac) 5 A 1/6 hp |
| Variable Power | 115 V (ac) 2.4 A |
| Sensors | NTC thermistor, 10 kΩ @ 77°F (25°C ±0.2°C) ß=3892 |
| -Included | Outdoor Sensor 070 and 4 of Universal Sensors 082 |
| -Optional | tekmar type#: 033, 479 |
| Warranty | Limited 3 Year Warranty |
In most cases the current version of literature will work, otherwise use the piece of literature most closely matching the date code of your product.
|
Product Submittal |
Nov 2011 - Present |
|
|
Installation & Operation Manual |
Nov 2012 - Present (Dec. 2012 and newer models) |
|
|
Quick Setup Guide |
Dec 2011 - Present |
|
|
User Manual |
Dec 2011 - Present |
|
Installation & Operation Manual |
Dec 2011 - Nov 2012 (Models prior to Dec. 2012) |


24 V (ac) Transformer
009

24 V (ac) Transformer Kit 009K

tekmarNet® 4 Timer
033

Universal Sensor
078

tekmarNet® 4 Setpoint Control 161

tN2 Wiring Center
313

tN2 Wiring Center
314

tN4 Wiring Center
315

tN4 Wiring Center
316

tN4 User Switch
479

tN4 User Switch
480

tN4 User Switch
481

tN4 Gateway
482

tN4 Gateway
483

tekmarNet® 2 Thermostat
527

tekmarNet® 2 Thermostat
528

tekmarNet® 2 Thermostat
529

tekmarNet® 2 Thermostat
530

tekmarNet® Thermostat
552

tekmarNet® Thermostat
553

tekmarNet® Thermostat
557