The Mixing Control 360 is designed to operate a mixing valve using Outdoor Temperature Reset. It can be used in applications ranging from in-floor radiant to commercial baseboard systems for Boiler Return Protection with full reset. This control regulates a single heating water temperature through Mixing Outdoor Reset. It controls the mixing by opening or closing a floating action type mixing valve actuator (3 or 4 way valves), and also provides control of the mix system pump.
Advanced settings to fine-tune building requirements
Automatic Boiler Differential
CSA C US certified (approved to applicable UL standards)
Floating Action Mixing Control
Indoor Temperature Feedback (with optional indoor sensor)
Outdoor Temperature Reset
Powered mixing system pump output
Quick setup for easy installation and programming of control
Setback input for energy savings
Test sequence to ensure proper component operation
User comfort adjustment to increase or decrease building space temperature
Warm Weather Shut Down
| Control | Microprocessor control. This is not a safety (limit) control |
| Packaged weight | 3.1 lb. (1420 g) |
| Dimensions | 6-5/8" H x 7-9/16" W x 2-13/16" D (170 x 193 x 72 mm) |
| Enclosure | Blue PVC plastic, NEMA type 1 |
| Approvals | CSA C US, meets class B: ICES & FCC Part 15 |
| Ambient conditions | Indoor use only, 32 to 104°F (0 to 40°C), RH ≤90% Non-condensing |
| Power supply | 120 V (ac) ±10%, 50/60 Hz, 1300 VA |
| Floating output | 24 V (ac) 0.34 A 8 VA |
| Relays | 240 V (ac) 10 A 1/3 hp |
| Demand | 20 to 260 V (ac) 2 VA |
| Sensors | NTC thermistor, 10 kΩ @ 77°F (25°C ±0.2°C) ß=3892 |
| -Included | Outdoor Sensor 070 and 2 of Universal Sensor 082 |
| -Optional | tekmar type #: 033, 076, 077, 084 |
| Warranty | Limited 3 Year Warranty |
In most cases the current version of literature will work, otherwise use the piece of literature most closely matching the date code of your product.
|
Product Submittal |
Jan 2011 - Present |
|
|
Installation & Operation Manual |
Mar 2009 - Present |
Application Brochure |
Mar 2009 - Current |
More advanced application drawings can be found in our Solutions section.
RF Noise Interference |
May 2009 - Present |

tekmarNet® 4 Timer
033

Indoor Sensor
076

Indoor Sensor
077

Indoor Sensor
084

tN2 Wiring Center
313

tN2 Wiring Center
314

tN4 Wiring Center
315

tN4 Wiring Center
316

3-Way Mixing Valve
710

3-Way Mixing Valve
711

3-Way Mixing Valve
712

3-Way Mixing Valve
713

3-Way Mixing Valve
714

4-Way Mixing Valve
720

4-Way Mixing Valve
721

4-Way Mixing Valve
722

4-Way Mixing Valve
723

4-Way Mixing Valve
724

Actuating Motor
741