The tekmarNet® 2 House Control 402 is designed to operate all the mechanical equipment in a residential hydronic heating system, coordinating their operation through network communication. It can be used in applications ranging from a single zone of baseboard with an on/off boiler to multiple fan coils, mixed radiant floor heating zones, and a modulating/condensing boiler. This control regulates up to two heating water temperatures through Outdoor Temperature Reset and Indoor Temperature Feedback. It is capable of controlling a single on/off, two stage, or modulating boiler, a mixing device, Domestic Hot Water, setpoint loads, 4 on-board zone valves, and can expand up to 24 zones in total for each space heating water temperature.
Note: There are multiple products which the 402 can replace depending on the application. Some conditions apply; please contact Customer Service for more information.Automatic Boiler Differential
Boiler Protection
DHW Post Purge
DHW Priority (optional)
DHW control
Exercising
Expandable up to 48 zones
For use with tekmarNet®2 thermostats ONLY
Four 24 V (ac) powered zone outputs
Indoor Temperature Feedback
One touch overrides (with optional User Switch)
Only requires 2 Wires Per Zone
Outdoor Temperature Reset
Powered pump outputs
Setpoint operation
Single on/off, two stage, or modulating boiler control
System setback (with optional timer)
Variable speed, floating action, or proportional mixing control
Warm Weather Shut Down
Zone Synchronization
tN4 expansion terminals
| Control | Microprocessor control. This is not a safety (limit) control |
| Packaged weight | 1.4 lb. (640 g) |
| Dimensions | 5.5" H x 5.5" W x 2.25" D (140 x 140 x 57 mm) |
| Enclosure | Blue PC+ABS plastic, NEMA type 1 |
| Approvals | CSA C US, meets class B: ICES & FCC Part 15 |
| Ambient conditions | Indoor use only, 32 to 104°F (0 to 40°C), RH ≤90% Non-condensing |
| Power supply | 24 V (ac) ±10%, 60 Hz, 100 VA max, Class 2 |
| Control load | 2 VA |
| Zone valve/floating action load | 89 VA, 24 V (ac), 3.7 A for zones 1 to 4 plus floating action output |
| Boiler stage 1, 2 relays | 24 V (ac) 5 A |
| Pump power | 115 V (ac) 12 A max |
| Pump relays | 115 V (ac) 5 A, 1/6 hp |
| Variable pump | 115 V (ac) 2.4 A |
| Setpoint and DHW calls | Short, 0 - 32 V (ac) |
| Boil/Mix modulation output | 0 - 10 V (dc) 500 Ω min load impedance, 4 - 20 mA 1 kΩ max load impedance |
| Sensors | NTC thermistor, 10 kΩ @ 77°F (25°C ±0.2°C) ß=3892 |
| -Included | Outdoor Sensor 070 and 2 of Universal Sensors 082 |
| -Optional | tekmar type#: 033, 479 |
| Warranty | Limited 3 Year Warranty |
In most cases the current version of literature will work, otherwise use the piece of literature most closely matching the date code of your product.
|
Product Submittal |
Jan 2011 - Present |
|
|
Installation & Operation Manual |
Sep 2010 - Present |
|
|
Quick Setup Guide |
Sep 2010 - Present |
|
Installation & Operation Manual |
Jan 2010 - Sep 2010 |
Installing House Controls 400, 401, 402 and 403 with Modulating Boilers |
Mar 2011 - Present |
Modulating Boiler Interface Revision 8 |
Mar 2011 - Mar 2011 (Updated March 2011) |