The tekmarNet® 2 House Control 403 is designed to operate all of the mechanical equipment in a residential hydronic heating system, coordinating their operation through network communication. It can be used in applications ranging from a single zone of baseboard with an on/off boiler, to multiple fan coils, mixed radiant floor heating zones, and a modulating/condensing boiler. This control regulates up to two heating water temperatures through Outdoor Temperature Reset and Indoor Temperature Feedback. It is capable of controlling a single on/off, two stage, or modulating boiler, a mixing device, Domestic Hot Water, setpoint loads, 4 on-board zone pumps, and can expand up to 24 zones in total for each space heating water temperature.
Note: There are multiple products which the 403 can replace depending on the application. Some conditions apply; please contact Customer Service for more information.Automatic Boiler Differential
Boiler Protection
DHW Post Purge
DHW Priority (optional)
DHW control
Exercising
Expandable up to 48 zones
For use with tekmarNet®2 thermostats ONLY
Four 115 V (ac) powered zone outputs
Indoor Temperature Feedback
One touch overrides (with optional User Switch)
Only requires 2 Wires Per Zone
Outdoor Temperature Reset
Powered pump outputs
Setpoint operation
Single on/off, two stage, or modulating boiler control
System Setback (with optional Timer)
Variable speed, floating action, or proportional mixing control
Warm Weather Shut Down
Zone Synchronization
tN4 expansion terminals
| Control | Microprocessor control. This is not a safety (limit) control. |
| Packaged weight | 1.4 lbs (640 g) |
| Dimensions | 5.5" H x 5.5" W x 2.25" D (140 x 140 x 57 mm) |
| Enclosure | NEMA 1 rated, blue PC+ABS plastic |
| Approvals | CSA C US, meets class B: ICES & FCC Part 15 |
| Ambient conditions | Indoor use only, 32 to 104°F (0 to 40°C), RH 90% Non-condensing |
| Power supply | 24 V (ac) ±10% 60 Hz, 100 VA max, Class 2 |
| Control load | 2 VA |
| Floating action load | 89 VA, 24 V (ac), 3.7 A |
| Boiler stage 1, 2 relays | 24 V (ac) 5 A |
| Pump power | 115 V (ac) 12 A max |
| Pump relays | 115 V (ac) 5 A, 1/6 hp |
| Variable pump | 115 V (ac) 2.4 A |
| Setpoint and DHW calls | Short, 0 - 32 V (ac) |
| Boil/Mix modulating output | 0 - 10 V (dc) 500 Ω min load impedance, 4 - 20 mA 1 kΩ max load impedance |
| Sensors | NTC thermistor, 10k @ 77°F (25°C ± 0.2°C) ß=3892 |
| included | Outdoor Sensor 070 and 2 of Universal Sensors 082 |
| -Optional | tekmar type#: 033, 479 |
| Warranty | Limited 3 Year Warranty |
In most cases the current version of literature will work, otherwise use the piece of literature most closely matching the date code of your product.
|
Product Submittal |
Jan 2011 - Present |
|
|
Installation & Operation Manual |
Jul 2011 - Present |
|
|
Quick Setup Guide |
Sep 2010 - Present |
|
Installation & Operation Manual |
Sep 2010 - Jul 2011 |
Installing House Controls 400, 401, 402 and 403 with Modulating Boilers |
Mar 2011 - Present |
Modulating Boiler Interface Revision 8 |
Mar 2011 - Mar 2011 (Updated March 2011) |

24 V (ac) Transformer
009

24 V (ac) Transformer Kit 009K

tekmarNet® 4 Timer
033

Universal Sensor
078

tekmarNet® 4 Setpoint Control 161

tN2 Wiring Center
313

tN2 Wiring Center
314

tN4 Wiring Center
315

tN4 Wiring Center
316

tN4 User Switch
479

tN4 User Switch
480

tN4 User Switch
481

tN4 Gateway
482

tN4 Gateway
483

tekmarNet® 2 Thermostat
527

tekmarNet® 2 Thermostat
528

tekmarNet® 2 Thermostat
529

tekmarNet® 2 Thermostat
530

tekmarNet® Thermostat
552

tekmarNet® Thermostat
553

tekmarNet® Thermostat
557

3-Way Mixing Valve
710

3-Way Mixing Valve
711

3-Way Mixing Valve
712

3-Way Mixing Valve
713

3-Way Mixing Valve
714

4-Way Mixing Valve
720

4-Way Mixing Valve
721

4-Way Mixing Valve
722

4-Way Mixing Valve
723

4-Way Mixing Valve
724

Actuating Motor
741