The Universal Reset Module 423 is designed to operate all of the mechanical equipment in a hydronic heating system, except for zones, coordinating their operation through network communication. It can be used in applications ranging from a single zone of baseboard with an on/off boiler, to four temperature systems comprised of multiple fan coils, baseboard, mixed radiant floor zones, and two modulating/condensing boilers. This control regulates up to four space heating water temperatures through Outdoor Temperature Reset and Indoor Temperature Feedback. It is capable of controlling two on/off or modulating boilers, Domestic Hot Water, setpoint loads, and can expand up to 24 zones for each space heating water temperature (96 in total).
Automatic Boiler Differential
Boiler Protection
Controls up to 4 water temperatures (with use of up to 3 mix expansion modules)
DHW Post Purge
DHW Priority (optional)
DHW control
Exercising
Expandable up to 96 zones
Indoor Temperature Feedback
One touch overrides (with optional User Switch)
Outdoor Temperature Reset
Powered pump outputs
Setpoint operation
System Setback (with optional Timer)
Two on/off or two modulating boiler control
Warm Weather Shut Down
Zone Synchronization
| Control | Microprocessor PID control; This is not a safety (limit) control |
| Packaged weight | 1.83 lb. (830 g) |
| Dimensions | 3-5/8" H x 5-3/8" W x 9/16" D (92 x 137 x 14 mm) |
| Approvals | CSA C US, CSA/UL 61010-1, meets Class B: ICES & FCC Part 15 |
| Ambient conditions | Indoor use only, 32 to 122°F (0 to 50°C), RH 80% to 88°F (31°C), down to 50% from 104 to 122°F (40 to 50°C), Altitude <6560 feet (2000 m), Installation Category II, Pollution |
| Power supply | Provided by interconnected tekmarNet Zone Manager |
| Pump relays | 115 V (ac) 5 A, 1/6 hp |
| Combined load | 10 A Maximum (for DHW and Primary Pump) |
| DHW valve output | 24 V (ac) 8 VA Maximum |
| Modulation output | 0-10 V (dc) Minimum 2500 |
| Boiler relay | 115 V (ac) 5 A |
| Demands | 20-260 V (ac) / 0.1 VA @ 24 V |
| Sensors | NTC thermistor, 10 k @ 77°F (25°C ± 0.2°C) ß = 3892 |
| -Included | Outdoor Sensor 070 and Universal Sensor 082 |
| -Optional | tekmar type#: 078 |
| Warranty | Limited 3 Year Warranty |
In most cases the current version of literature will work, otherwise use the piece of literature most closely matching the date code of your product.
|
Product Submittal |
Jan 2011 - Present |
|
|
Installation & Operation Manual |
Aug 2007 - Present |
|
|
Job Record |
Aug 2009 - Present |
|
|
Wiring Brochure |
Mar 2009 - Present |
Installing tN4 Reset Modules 420, 422 and 423 with Modulating Boilers |
Mar 2011 - Present |
|
RF Noise Interference |
May 2009 - Present |
Modulating Boiler Interface Revision 8 |
Mar 2011 - Mar 2011 (Updated March 2011) |

Universal Sensor
078

tekmarNet® 4 Setpoint Control 161

tekmarNet® 4 Setpoint Control 162

Boiler Control
274

Boiler Control
275

Boiler Control
284

tN4 Zone Manager
335

tN4 Zone Manager
336

tN4 Dual Zone Manager
337

Mixing Expansion Module
440

Mixing Expansion Module
441

Mixing Expansion Module
444

tN4 Gateway
482

tN4 Gateway
483