The tekmarNet® 4 Dual Zone Manager 337 is designed to provide a zoning solution for heating systems. It can be used in applications ranging from baseboard zones, to radiant heating manifolds. This product can operate up to 6 zone valves in 2 groups. It is capable of providing power for up to 6 tekmarNet® 4 or stand alone thermostats and energizing their respective 24 V (ac) zones, as well as providing two separate Zone Group Pump (powered end switch) contacts to enable an external device such as a manifold pump. Zone Group Pump A is for zones 1-3 and Zone Group Pump B can be activated if zones 4-6 call for heat.
CSA C US Certified for use in USA and Canada
Internal 50 VA transformer
Provides power to tekmarNet® 4 Reset Module
Simple wiring
Three powered zone valve outputs on tekmarNet® 4 Bus A
Three powered zone valve outputs on tekmarNet® 4 Bus B
Time delay for thermal motor zone valves
Two powered zone group pump outputs (A and B)
tekmarNet® 4 compatible
| Control | Microprocessor control. This is not a safety (limit) control |
| Packaged weight | 5.5 lb. (2490 g) |
| Dimensions | 8-1/16" H x 11-1/8" W x 2-15/16" D (204 x 282 x 74 mm) |
| Enclosure | Blue PC+ABS plastic with metal top and bottom conduit connection walls, NEMA type 1 |
| Approvals | CSA C US, meets Class B: ICES & FCC Part 15 |
| Ambient conditions | Indoor use only, 32 to 122°F (0 to 50°C), RH ≤80% to 88°F (31°C), down to 50% above 104°F (40°C), Altitude <6560 ft. (2000 m), Installation Category II, Pollution Degree |
| Power supply | 115 V (ac) +/- 10%, 60 Hz, 15.5 A, fuse T15 A 250 V |
| Transformer power available | 24 V (ac) 50 VA, fuse T2.5 A 250 V |
| Zone group pump A relay | 115 V (ac) 5 A |
| Zone group pump B relay | 115 V (ac) 5 A |
| Combined load on input power | 15 A max |
| Group pump B demand | 24 V (ac) < 0.1 VA |
| Warranty | Limited 3 Year Warranty |
In most cases the current version of literature will work, otherwise use the piece of literature most closely matching the date code of your product.
|
Product Submittal |
Jan 2011 - Present |
|
|
Installation & Operation Manual |
Jun 2005 - Present |
|
|
Job Record |
Aug 2009 - Present |
|
|
Wiring Brochure |
Dec 2008 - Present |

tN4 Zone Expansion Module 325

tN4 Zone Expansion Module 326

Boiler Reset Module
420

Mixing Reset Module
421

Universal Reset Module
422

Universal Reset Module
423

tN4 Gateway
482

tN4 Gateway
483

tekmarNet® 4 Thermostat
537

tekmarNet® 4 Thermostat
538

tekmarNet® 4 Thermostat
540

tekmarNet® 4 Thermostat
541

tekmarNet® 4 Thermostat
542

tekmarNet® 4 Thermostat
543

tekmarNet® 4 Thermostat
544

tekmarNet® 4 Thermostat
545

tekmarNet® 4 Thermostat
546

tekmarNet® Thermostat
552

tekmarNet® Thermostat
553

tekmarNet® Thermostat
557