The tekmarNet® thermostat 552 is a communicating touchscreen thermostat designed for hydronic heating systems. The extra large touchscreen display allows you to easily adjust 7-day programmable schedules and room temperatures to optimize comfort and energy savings. It operates a single zone of heating and has two auxiliary sensor inputs that can be assigned to measure room, floor, or outdoor temperature. An optional floor sensor allows precise heating of radiant floors by controlling the floor temperature and maintaining the desired room air temperature. Alternatively the room air temperature sensor can also be disabled to solely maintain a minimum floor temperature. The 552 can be wired using 2 or 4 wires to connect to tekmarNet® zoning controls, or can be installed as a stand-alone thermostat using 3 wires.
2 Auxiliary Sensor Inputs
Air Group Member
Auto Heating Cycle
Away Scene Key
Backlight
Exercising
Floor Warming (with 079 slab sensor)
Freeze Protection
Optional Floor Temperature Display
Outdoor Temperature Display
Programmable setback schedule
Pulse Width Modulation
Room Temperature Limiting
Supports Radiant Floor Cooling
Touchscreen Technology
Warm Weather Shut Down
Zone Post Purge
Zone Synchronization
tekmarNet® Communication Compatible
| Control | Microprocessor control. This is not a safety (limit) control |
| Packaged weight | 0.8 lb. (350 g) |
| Dimensions | 5" H x 3-1/4" W x 15/16" D (127 x 82 x 23 mm) |
| Enclosure | White ABS / PC plastic |
| Approvals | Meets Class B: ICES & FCC Part 15 |
| Ambient conditions | Indoor use only, 32 to 122°F (0 to 50°C), RH ≤90% non-condensing |
| Power supply | 24 V ±10%, 50/60 Hz, 1.8 VA Standby, 56 VA fully loaded, NEC / CEC Class 2 |
| Relay | 24 V (ac) 2 A |
| Sensor(s) | NTC thermistor, 10 kΩ @ 77°F (25°C ±0.2°C) ß=3892 |
| Included | None |
| -Optional | tekmar type # 070, 072, 073, 076, 077, 078, 079, 084 |
| Warranty | Limited 3 Year Warranty |
In most cases the current version of literature will work, otherwise use the piece of literature most closely matching the date code of your product.
|
Product Submittal |
Jul 2011 - Present |
|
|
Installation & Operation Manual |
Aug 2011 - Present |
|
|
Quick Setup Guide |
Aug 2011 - Present |
|
|
User Manual |
Aug 2011 - Present |


Outdoor Sensor
070

Indoor Sensor
076

Indoor Sensor
077

Slab Sensor
079

Indoor Sensor
084

tN2 Wiring Center
313

tN2 Wiring Center
314

tN4 Wiring Center
315

tN4 Wiring Center
316

tN2 Zone Expansion Module 324

tN4 Zone Expansion Module 325

tN4 Zone Expansion Module 326

tN2 Zone Manager
334

tN4 Zone Manager
335

tN4 Zone Manager
336

tN4 Dual Zone Manager
337

tN2 House Control
400

tN2 House Control
401

tN2 House Control
402

tN2 House Control
403

tN2 House Control
406

tN4 Gateway
482

tN4 Gateway
483