System Requirements |
||||||||||||||||||||
|
Heat Stages 2 Stage Example: Radiant 1st stage & fan coil 2nd stage |
1 |
1 |
1 | 1 |
1 |
1 |
2 |
1 |
1 |
1 |
1 |
2 |
1 |
2 |
2 |
|||||
|
Cool Stages 2 Stage Example: Radiant cooling 1st stage & dx coil 2nd stage |
- |
- |
- | - |
- |
- |
- |
1 |
- |
- |
1 |
- |
1 |
1 |
2 |
- |
||||
|
Heat Pump Stages For direct control of heat pump from thermostat |
- |
- |
- |
- | - |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
|||
|
Fan / ERV / HRV Stages 2 Stage Example: Low speed fan 1st stage with high speed 2nd stage |
- |
- |
- |
- | - |
- |
- |
- |
1 |
- |
- |
1 |
- |
1 |
1 |
2 |
- |
|||
|
Auxiliary Sensor Inputs Number of external sensor connections |
2 |
2 |
2 |
1 | 1 |
- |
1 |
1 |
- |
- |
1 |
- |
2 |
2 |
2 |
3 |
2 |
2 |
3 |
|
|
Auxiliary Sensor Input Options Support a wider range of applications with these types of external sensors |
Outdoor |
|
|
|
- |
|
|
- |
|
|
- |
|||||||||
| Room |
|
|
|
- |
|
|
- |
|
|
- |
||||||||||
| Floor |
|
|
|
- |
|
|
- |
|
|
- |
||||||||||
| Duct | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | |||||
| Coil | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | |||||
| Humidity | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | ||
|
Humidity Control On-board humidity sensor |
- |
- |
- |
- | - |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
|
||
|
tekmarNet® Communication - 2 or 4 wire Number of conductors for power & communication in tekmarNet® system |
- |
- |
- |
- | - |
4 |
4 |
4 |
4 |
4 |
4 |
4 |
2 or 4 |
2 or 4 |
2 or 4 |
|||||
|
Radiant Floor Heating Designed to operate for maximum comfort |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||||
|
Radiant Floor Cooling Combine radiant floor systems & heat pumps for cooling |
- |
- |
- |
- | - |
|
|
|
|
|
|
|
- |
- |
- |
- |
|
|
||
|
Features & Benefits |
||||||||||||||||||||
|
Built-In Programmable Schedule Program savings without affecting comfort |
|
|
|
- | - |
- |
- |
- |
- |
- |
- |
- |
|
|
|
|
|
|
||
|
Touchscreen Technology Large touchscreen makes programming easy |
- |
- |
- |
- | - |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
|
|
||
|
Remote Monitoring Access tekmarNet® systems via the internet with a Gateway 483 |
- |
- |
- |
- | - |
|
|
|
|
|
|
|
|
|
|
|
|
|
||
|
System Wide Control Add a User Switch to quickly override all networked thermostats |
- |
- |
- |
- | - |
|
|
|
|
|
|
|
|
|
|
|
|
|
||
|
Zone Synchronization Coordinate heat demands, minimize equipment cycling |
- |
- |
- |
- | - |
|
|
|
|
|
|
|
|
|
|
|
|
|
||
|
Air Group Master Prevent heating & cooling from running simultaneously & operate multiple heating zones within a single cooling zone |
- |
- |
- |
- | - |
- |
- |
- |
|
- |
- |
|
- |
- |
|
|
- |
|
||
|
Air Group Member Participate in an 'Air Group' controlled by the 'Air Group Master' |
- | - | - | - | - | - | - | - | - | |||||||||||
|
Supports Network Scheduling Centralized scheduling for all thermostats |
- |
- |
- |
- | - |
|
|
|
|
|
|
|
|
|
|
|
|
|
||
|
Integrate with Home Automation Systems Connect to home automation systems with a Gateway 482 |
- |
- |
- |
- | - |
|
|
|
|
|
|
|
|
|
|
|
|
|
||
|
Add a Wiring Center or Zone Manager Simple, quick installation & troubleshooting |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||||
|
Conventional Heat/Cool Equipment Applications |
552 |
553 |
557 |
|
Single Stage Heat |
|
|
|
|
1 Heat, 1 Cool, 1 Fan, Relative Humidity |
|
|
|
|
2 Heat, 1 Fan, Humidification |
|
|
|
|
2 Heat, 1 Cool, 1 Fan |
|
|
|
|
2 Heat, 2 Cool, Fan, Relative Humidity |
|
|
|
|
|
|
|
|
|
Ducted Heat Pump System Applications |
552 |
553 |
557 |
|
1 Radiant Floor, 1 Heat Pump, Relative Humidity |
|
|
|
|
1 Radiant Floor, 1 Heat Pump, Backup Heat |
|
|
|
|
1 Radiant Floor, 1 Heat Pump, 1 Fan |
|
|
|
|
1 Radiant Floor, 2 Heat Pump, 1 Backup Heat, Relative Humidity |
|
|
|
|
|
|
|
|
|
Hydronic Heat Pump System Application |
552 |
553 |
557 |
|
1 Radiant Floor, 1 Fan Coil Heat/Cool, Relative Humidity |
|
|
|
|
Features & Benefits |
|||||||||||
|
tekmarNet® Communication - 2 or 4 wire Select number to match thermostats |
2 |
2 |
4 |
4 |
2 |
4 |
4 |
4 |
2 |
4 |
4 |
|
Zone Control with Valves (V) or Pumps (P) Includes number of onboard zone outputs |
4 V |
4 P |
6 V |
4 P |
4 V or P |
6 V |
4 P |
3V + 3V |
4 V or P |
6 V |
3 P |
|
Built-in End Switch Enables an external device such as a boiler |
|
|
|
|
- |
- |
- |
- |
- |
- |
- |
|
Zone Group Pump Local 115 V (ac) pump output |
1 |
- |
1 |
- |
1 |
1 |
1 |
2 |
1 |
1 |
1 |
|
Remote Manifold Wiring Center Provides convenient wiring with 2 conductors to mechanical room |
|
|
|
|
- |
- |
- |
- |
- |
- |
- |
|
Supports Classic Thermostats Combine tekmar zone solutions with standard thermostats |
- |
- |
|
|
- |
- |
- |
- |
- |
- |
- |
|
Built-In Transformer Convenient internal transformer for 24 V (ac) controls |
- |
- |
- |
- |
|
|
|
|
|
|
|